Skip to main content
Offer$500 off + a free 3D layout
Valley Decks
Completed deck frame with doubled beam, joists at even spacing and joist tape

Resource

Deck Joist Span Chart: How Far Can Joists Span in Idaho?

Under the 2018 IRC that Idaho adopts, a Douglas fir-larch or hem-fir 2x8 joist spans 11 ft 1 in at 16 inches on center, a 2x10 spans 13 ft 7 in and a 2x12 spans 15 ft 9 in.

All resources

Updated

Offer$500 off + a free 3D layout

Get a deck estimate

All fields are required.

Prefer to talk? Call or text (208) 330-5348

Submitting this form does not book an appointment.

Where do Idaho's deck span tables come from?

From Section R507 of the 2018 International Residential Code, which Idaho adopts with state amendments as the Idaho Residential Code, 2020 Edition. Boise reviews residential projects to the 2018 IRC, and the deck tables in R507 give a deck plan a prescriptive path through that review.

Prescriptive means the code has already done the engineering for common cases. If your joists, beams and footings fall inside the tables, the plan reviewer can check the framing against them without asking for calculations. Those tables are built on a 40 psf live load and a 10 psf dead load, the weight of people and furniture plus the weight of the deck itself.

The American Wood Council's DCA 6 guide is the companion document. It turns the same prescriptive approach into drawings and details, on the same 40 psf live load basis. It isn't code, but it is a handy way to see what a complete framing plan shows.

Be clear about what a span chart does. It tells you what your framing plan has to show. It does not replace plan review, it doesn't cover every situation, and some decks need an engineer no matter what the chart says. Those cases are listed further down.

Joist span chart (IRC Table R507.6)

Find your lumber species, pick the joist spacing, and read the maximum span for each joist size. The span is the clear distance between supports, such as from the ledger to the beam, not the overall length of the board.

Maximum joist spans, IRC Table R507.6 (40 psf live / 10 psf dead)
Joist sizeDF-larch / hem-fir @ 12 inDF-larch / hem-fir @ 16 inSouthern pine @ 12 inSouthern pine @ 16 in
2x812 ft 6 in11 ft 1 in13 ft 1 in11 ft 10 in
2x1015 ft 8 in13 ft 7 in16 ft 2 in14 ft 0 in
2x1218 ft 0 in15 ft 9 in18 ft 0 in16 ft 6 in

Read across a row to see what tighter spacing buys you. A Douglas fir-larch 2x10 at 16 inches on center reaches 13 ft 7 in; tighten the spacing to 12 inches and the same board reaches 15 ft 8 in. Read down a column to see what a deeper joist buys you at the same spacing.

The species column matters. The grade stamp on each board names the species group, and in this chart southern pine spans run up to 9 inches longer than Douglas fir-larch or hem-fir, matching them only for a 2x12 at 12 inches. Using the southern pine column for hem-fir lumber is a real error, not a rounding difference.

We have only reproduced the rows we verified against the adopted code: 2x8, 2x10 and 2x12 joists at 12 and 16 inches on center for those two species groups. This chart leaves out 2x6 joists, 24-inch spacing and spruce-pine-fir. If your plan uses any of those, read the full table in the code rather than guessing from these rows.

Deck joists resting on a doubled beam over posts
Illustration: deck joists on a beam. Not a Valley Decks project photo.

Worked examples: a 12x16 and a 16x20 deck

These are our own readings of the table, not designs. Take a 12x16 deck attached to the house, with joists running about 12 feet from the ledger out to a beam. A Douglas fir-larch 2x8 at 16 inches reaches only 11 ft 1 in, so it falls short. The same 2x8 at 12 inches reaches 12 ft 6 in, and a 2x10 at 16 inches reaches 13 ft 7 in; either would cover the span. The choice then comes down to decking spacing, lumber cost and how deep you want the frame.

Now a 16x20 deck with joists running about 16 feet. A Douglas fir-larch 2x12 at 16 inches stops at 15 ft 9 in, so it falls short; at 12 inches it reaches 18 ft 0 in. If the lumber is stamped southern pine, a 2x12 at 16 inches reaches 16 ft 6 in. The other option is a second beam that cuts the span in half, which lets smaller joists work but adds posts and footings. Our 12x16 deck cost guide and 16x20 deck cost guide show how those framing choices show up in a budget.

How far can a joist cantilever past the beam?

One-quarter of the joist's span, or the table's maximum cantilever, whichever is less. The table maximum is often the smaller number.

The verified example: a Douglas fir-larch 2x8 at 16 inches on center spans 11 ft 1 in, and one-quarter of that is about 2 ft 9 in. The table caps that joist's cantilever at 2 ft 1 in, so 2 ft 1 in is the limit, not 2 ft 9 in. Treat the quarter-span figure as a ceiling, never a target.

A cantilever pulls the beam and its posts back under the deck, out of sight and away from the edge. If your plan relies on one, check the table value for that exact joist, species and spacing rather than applying the quarter-span rule alone.

Beam spans (IRC Table R507.5)

The beam carries the outer ends of the joists down to the posts, and Table R507.5 sets how far a beam may span between posts based on the beam size and the joist span it supports. Longer joists put more load on the beam, so the allowable beam span drops as the joists get longer.

Selected beam spans, IRC Table R507.5 (southern pine). Beams may cantilever ¼ of the span past the post.
BeamJoist span it carriesMaximum beam span
2-2x1012 ft7 ft 4 in
3-2x1212 ft10 ft 9 in
3-2x1214 ft10 ft 0 in
3-2x1216 ft9 ft 4 in

Read the 3-2x12 rows to see the trade-off. Carrying 12-foot joists, that beam may span 10 ft 9 in between posts; carrying 16-foot joists, it drops to 9 ft 4 in. A 16-foot-deep deck therefore tends to need more posts along its beam than a 12-foot-deep one, even with the same beam.

These rows are southern pine only. We haven't reproduced the Douglas fir-larch or hem-fir beam rows, and the values differ by species, so a plan must cite the table row for the species actually used.

Caldwell's Typical Porch/Deck Section handout (DWG 12-06) shows the common local arrangement: a doubled 2x beam bolted to 4x4 posts that sit on approved post bases, with joists either set in approved hangers or bearing on a ledger. It is a reference drawing showing what a permit set should include, not a recommendation for your deck.

How big do the footings get? (Table R507.3.1)

Footing size depends on the deck area each post carries and the soil's bearing value. At 1,500 psf soil bearing, Table R507.3.1 runs from a 14-inch square footing for small tributary areas up to a 22-inch square footing for 100 square feet.

Footing sizes, IRC Table R507.3.1 (1,500 psf soil)
Tributary areaSquare footingRound footingThickness
Up to 40 sq ft14 in16 in6 in
Up to 60 sq ft17 in19 in6 in
Up to 100 sq ft22 in25 in8 in

Tributary area is the patch of deck whose weight ends up on one post. As a rough illustration of our own, take an attached deck with 12-foot joists running from the ledger to a single beam, and beam posts 8 feet apart. The ledger carries one end of each joist and the beam the other, so each post picks up half the joist span along its share of the beam: about 8 by 6 feet, or 48 square feet, which lands in the 60-square-foot row. Your plan reviewer checks the real number, including any cantilever.

Depth is a separate rule. Footings go below the frost line, which is 24 inches in Boise, Meridian, Star, Caldwell and unincorporated Canyon County. Middleton lists 24 inches or the depth in a geotechnical soils report. Garden City's permit application shows 1,500 psf soil bearing in its design-criteria block, but the city labels that block an example only and expects plans to state their own criteria, so don't treat it as a published soil value. The only pier-block exception in R507 is for freestanding decks of 200 square feet or less and 20 inches or less above grade. Our deck footing depth guide covers the rest.

Why valley snow loads don't change the span tables

Every published ground snow load in the valley sits below the 40 psf the span tables are built on. The deck tables already carry more than the snow these jurisdictions design for, so for an ordinary open deck the live load controls.

Treasure Valley snow loads vs the 40 psf table basis
JurisdictionGround snow loadUnder the 40 psf basis?
Boise20 psfYes
Star20 psfYes
Caldwell20 psfYes
Middleton20 psfYes
Canyon County (unincorporated)25 psfYes
Emmett30 psfYes
Avimor / Valnova (Eagle)Special snow-load areasStamped plans required

The ledger fastener table, R507.9.1.3(1), states its basis outright: 40 psf live load, 10 psf dead load, snow load of 40 psf or less, with snow not acting at the same time as the live load. DCA 6 likewise says it does not cover snow loads above 40 psf, and it excludes hot tubs.

Two exceptions matter locally. Eagle's submittal checklist requires stamped plans in Avimor and Valnova, which it treats as special snow-load areas. And a deck under a roof edge can collect sliding or drifting snow well beyond the ground value. Our deck snow load guide covers drift and covered decks in detail.

What joist spacing does composite decking need?

Whatever the board manufacturer specifies. R507 says composite decking is installed to the manufacturer's instructions and must have a flame spread index of 200 or less, so the decking, not just the joist table, can set your spacing.

Trex's decking installation guide calls for joists at 16 inches on center for residential use and 12 inches for commercial. A joist size that would span the distance at 24 inches doesn't help if the boards are rated for 16. Plan the spacing around the decking first, then pick the joist size that spans at that spacing.

Trex also sets the gap at board ends by temperature: 1/8 inch when installed above 40°F and 3/16 inch below 40°F. That matters here. NOAA's 1991–2020 normals for the Boise Air Terminal show 108 nights a year at or below 32°F, with the median last spring freeze on April 24 and the first fall freeze on October 21. A cold morning start in October or April can put the boards in the below-40°F range, and the gap has to follow the installation temperature.

TimberTech and Fiberon publish their own spacing and gapping rules, which we haven't verified for this page. If you're using one of those boards, read that manufacturer's current installation guide before the framing is laid out. We don't reproduce the code's decking span table here. For the material choice itself, see composite decks and our composite vs wood decking comparison.

How do ledgers and lateral hardware fit the framing plan?

Where the deck attaches to the house, the ledger carries the inner ends of the joists, and R507.9.1 sets how it is fastened. Its fastener table uses the same 40 psf live and 10 psf dead basis, with snow at or under 40 psf. Ledger fasteners must be hot-dipped galvanized or stainless steel, and a ledger may not be attached to stone or masonry veneer.

R507.8 bans toenails and nails loaded in withdrawal for the deck-to-house connection, and says that where a positive connection to the house can't be verified at inspection, the deck must be self-supporting. R507.9.2 gives one prescriptive way to meet the lateral requirement: two hold-down tension devices of at least 1,500 pounds within 24 inches of each end of the deck, or four rated at 750 pounds or more. Our deck ledger board repair guide explains the ledger in depth, including what to check on an older deck's house connection.

When do the span tables stop applying?

When the deck carries loads or sits in conditions the tables weren't written for. Then an engineer designs the framing instead.

The tables also stop at their own edges: a joist span longer than the table lists, a species or size the table doesn't cover, or a beam carrying a point load from a roof post. In each case the fix is the same: a design that shows its own numbers rather than pointing at a table row.

How we use the span chart on a project

We lay out the deck first, then choose joist size, spacing and beam lines that fit that layout and the decking you've picked. The framing plan and the footing-to-rail section go into the permit submittal; Boise's #406 checklist asks for both, along with a site plan and elevations. In Eagle, the checklist also requires the plans to state the design loads, live, dead and snow, along with the frost depth and wind criteria.

During the build, inspections compare what was built with what was approved. In Boise the footing inspection comes before any concrete is placed, so footing size and depth are checked in the open; the later inspections are commonly framing and final, but confirm the sequence with the city that issues your permit. Changing joist size, spacing, beam size or post locations on site means changing the plans too. When you're ready to price a layout, the deck cost calculator gives a starting range, and you can request an estimate for a measured quote.

Span chart mistakes to avoid

  1. Reading the southern pine column for hem-fir or Douglas fir-larch lumber. Check the grade stamp.
  2. Cantilevering past one-quarter of the span, or past the table maximum when that is smaller.
  3. Framing at 24 inches on center under composite boards rated for 16.
  4. Skipping the cold-weather end gap on composite boards cut and installed below 40°F.
  5. Laying new decking over old joists without checking their size, spacing and condition against the table.
  6. Using a span chart from a different code edition, or a 2x6 or 24-inch row nobody has checked against the adopted code.
  7. Treating the beam span as fixed when the joists get longer. Longer joists shorten the allowable beam span.

Loads come first: our deck snow load guide explains the 40 psf basis and drift. The bottom of the load path is in the footing depth guide, and the house connection is in deck ledger board repair. For the guard and stair rules on top of the frame, read the Idaho deck railing and stair code, and for decks built to carry a spa, see hot tub deck ideas. To put numbers on a layout, try the deck cost calculator.

Frequently asked questions

How far can a 2x8 deck joist span?
Under 2018 IRC Table R507.6, a Douglas fir-larch or hem-fir 2x8 spans 12 ft 6 in at 12 inches on center and 11 ft 1 in at 16 inches. Southern pine 2x8s span 13 ft 1 in and 11 ft 10 in at the same spacings. Those values assume a 40 psf live load and 10 psf dead load, and the span is the clear distance between supports.
How far can a 2x10 joist span at 16 inches on center?
13 ft 7 in for Douglas fir-larch or hem-fir and 14 ft 0 in for southern pine, under 2018 IRC Table R507.6. At 12 inches on center those rise to 15 ft 8 in and 16 ft 2 in. Check the grade stamp on the lumber, because using the southern pine column for hem-fir boards overstates the span.
How far can deck joists cantilever past the beam?
One-quarter of the joist span or the table maximum, whichever is less, under the 2018 IRC. For a Douglas fir-larch 2x8 at 16 inches on center, the span is 11 ft 1 in, so a quarter would be about 2 ft 9 in, but the table caps the cantilever at 2 ft 1 in. The smaller number is the limit.
What joist spacing does Trex require on a residential deck?
Trex's decking installation guide calls for joists at 16 inches on center on residential decks and 12 inches on commercial ones. The 2018 IRC says composite decking is installed to the manufacturer's instructions, so that spacing applies even where the joist table would allow wider. Trex also sets end gaps by temperature: 1/8 inch above 40°F and 3/16 inch below.
Do Treasure Valley snow loads change the deck span tables?
Not for an ordinary open deck. The IRC deck tables assume a 40 psf live load, and published ground snow loads in the valley run from 20 psf in Boise, Star, Caldwell and Middleton to 25 psf in unincorporated Canyon County and 30 psf in Emmett. Drift from a roof edge, and Eagle's Avimor and Valnova special snow-load areas, are the exceptions.
When does a deck need engineered plans instead of the span tables?
When it falls outside what the tables cover. Hot tubs and snow loads above 40 psf are excluded from DCA 6. Boise's #406 checklist requires stamped engineering for any deck taller than six feet above grade, Eagle requires stamped Idaho-engineer plans for beams, connections and non-prescriptive bracing, and Eagle's Avimor and Valnova areas need stamped plans for snow load.

Sources

  1. 2018 IRC as adopted in Idaho, Chapter 5 (R507 Exterior Decks) — UpCodes
  2. ICC — 2018 International Residential Code, Chapter 5 Floors
  3. Idaho DOPL — Adopted building codes (2025 update)
  4. City of Boise — 301 Current Building Codes (2018 IRC design criteria)
  5. American Wood Council — DCA 6, Prescriptive Residential Wood Deck Construction Guide (2015 IRC basis)
  6. Trex — Decking Installation Guide (span chart and gapping)
  7. City of Boise — #406 Residential Addition, Alteration & Accessory Building Submittal Checklist (July 2025)
  8. City of Boise — Building Inspections
  9. City of Eagle — New Residential Building/Addition Submittal Checklist (2023)
  10. City of Star — Adopted Codes & Design Criteria (115 mph wind, Exposure C, 24-in frost)
  11. City of Caldwell — Code Resources (2018 IRC; 24-in frost, 115 mph wind, 20 psf ground / 25 psf roof snow)
  12. City of Middleton — Design Criteria (dated 2024-05-24)
  13. Canyon County — Building Department (unincorporated design criteria, Table R301.2(1))
  14. City of Caldwell — Typical Porch/Deck Section handout (DWG 12-06)
  15. City of Meridian — Residential Detached Accessory Structures handout (rev. 3/15/2021)
  16. Garden City — Residential Building Permit Application (4/25/2023; design criteria block marked "EXAMPLE ONLY")
  17. City of Emmett — Building Department design requirements
  18. NOAA NCEI U.S. Climate Normals 1991–2020, Boise Air Terminal (USW00024131) — annual/seasonal

Last reviewed .

Keep reading

All resources

Next step

Ready to price your deck?

Tell us the size, the material you're leaning toward and when you'd like it built. We'll follow up to schedule an on-site measure.

CallGet a deck estimate